Products> PH Sensor> Plastic PH Electrode> Online Analog PH Sensor for Sewage Water
Send Inquiry
*
*
Online Analog PH Sensor for Sewage Water
Online Analog PH Sensor for Sewage Water
Online Analog PH Sensor for Sewage Water
Online Analog PH Sensor for Sewage Water
Online Analog PH Sensor for Sewage Water

Online Analog PH Sensor for Sewage Water

Get Latest Price
    Measuring range
    option
    Contact Now
    Share:

    Model No.ASP400

    BrandDaruifuno

    CertificationISO9001

    Working Pressure0~6bar

    Working Temperature0~100℃

    Reference ElectrodeAg/AgCl

    Shaft MaterialPPS

    Place Of OriginChina

    Product Nameonline pH sensor

    Reference ElectrolyteKCl gel

    Description
    Product Description

    The ASP400 series of Analog PH Sensors developed and produced by Daruifuno has an upgraded shell material based on the ASP300. The PH Sensor is made of high-temperature-resistant and corrosion-resistant PPS material and is more suitable for monitoring the pH value of various types of sewage. The internal structure of the ASP400 sensor has also been improved, making it more stable, faster in response and longer in life when measuring pH. Temperature has an impact on pH value. ASP400 is divided into ASP400V without temperature sensor, ASP400N with NTC10K temperature sensor and ASP400T with built-in PT1000 temperature sensor. Users can choose the appropriate electrode according to their own needs. The cable length of the pH electrode can also be predetermined. The default is 5 meters and can be customized up to 60 meters.

    ?

    Features

    The pH sensor?uses a low-impedance hemispherical glass membrane, which is high in strength and not easily broken.
    Double salt bridge design, filled with large capacity KCl gel, long service life
    Large area annular porous PTFE separator, fast penetration, fast response, not easy to block
    Reinforced PPS shell packaging, resistant to high temperature and corrosion, suitable for all types of sewage
    There are 1-inch NPT mounting threads at the beginning and end for easy installation.
    Optional protective cover with cleaning interface can be connected to the air pump to achieve automatic underwater cleaning.

    ?

    Specification

    Model ASP400V ASP400N ASP400T
    Measuring Range 0~14pH
    Indicating electrode Low impedance hemispherical glass membrane
    Reference System Ag/AgCl reference electrode
    Temperature Unit No temperature NTC10K PT1000
    Electrode Material PPS+glass+porous PTFE diaphragm
    Zero(E0)pH pH 6.86 buffer solution: 6.86±0.3 pH
    Slope(SLOP)% pH 4.01 pH 6.86 buffer solution>95%
    Flow rate 0.5m/s≥flow rate≥0.001m/s
    Working Pressure 0~6bar
    Working Temperature 0~100℃
    Thread Size 1 inch NTP thread (both ends)
    Dimension Diameter: 35mm Length: 200 mm
    Cable default 5 meters,other length can be custom

    ?

    Structure

    The pH sensor is a component that directly responds to the pH value in the solution. It consists of a glass rod and a low-end glass hydrogen ion sensitive membrane. When the sensitive membrane comes into contact with an aqueous solution, a gel layer forms on its outside. At the same time, since the sensor is filled with an aqueous electrolyte solution, there is also a layer of gel inside the membrane. The hydrogen ions in and around the gel layer will leak out or penetrate into the gel layer according to the concentration of hydrogen ions in the test solution, that is, the pH value. If the solution is alkaline, H+ will leak out and a negative charge will form on the outside of the membrane. Since the electrolyte inside the sensor has a constant pH value, the potential on the inner surface of the membrane remains constant during the measurement process. This results in different charges inside and outside the pH sensor.

    Analog PH Sensor Structure

    ?

    Maintenance

    The electrode of the pH sensor cannot be left in a dry state for a long time, otherwise it will fail due to dehydration. At this time, you can try to soak the electrode in a pH 4.0 buffer for 24 hours, and then take it out to check whether the detection function has been restored. If it still does not work properly, you can only replace the new electrode. If the pH electrode is not used for a long time, you can add a saturated KCL solution to the factory protective cap for preservation.

    ASP400 series analog pH sensors have high accuracy, good stability, fast response speed and long life. They are widely used in industrial wastewater, municipal sewage, domestic sewage and other occasions. We provide a variety of matching online pH controllers.?Daruifuno?has focused on the research and development and production of water quality analysis instruments for more than ten years. Our main products include pH ORP analyzers, conductivity analyzers, turbidity analyzers, COD analyzers, dissolved oxygen analyzers, ammonium analyzers, chlorine analyzers, etc. If you are interested in our products, please contact us.

    ?

    Contact Us Now
    Enter your inquiry details, We will reply you in 24 hours.
    Please fill in the information
    * Please fill in your e-mail
    * Please fill in the content
    People who viewed this item also viewed
    Products> PH Sensor> Plastic PH Electrode> Online Analog PH Sensor for Sewage Water
    Send Inquiry
    *
    *

    We will contact you immediately

    Fill in more information so that we can get in touch with you faster

    Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

    Send